MIMAKI JF-1631 Spezifikationen Seite 107

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 142
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 106
4-39
Replacing UV lamp
4
Daily Maintenance
4
Pull out the exhaust blower Assy
upward.
After removing the finger screws on the top part of
the exhaust blower Assy, pull out the exhaust
blower Assy.
5
Remove UV lamp cassette.
(1) Remove the bolt on the front of the UV lamp cassette
using supplied hexagonal wrench.
(2) Pull off the UV lamp cassette.
6
Place a new UV lamp.
Fix the bolt on the front of the UV lamp cassette
using supplied hexagonal wrench.
7
Fix the exhaust blower Assy and
tighten the finger screw.
8
Connect the connector of the exhaust blower connecting cable.
9
Fix the front right cover and front left cover and switch ON the
power.
When the replacement is completed, perform the procedures of P.4-40 "Resetting UV
lamp irradiation duration".
Pull out
Exhaust blower Assy
UV lamp cassette
Remove
Fix
Seitenansicht 106
1 2 ... 102 103 104 105 106 107 108 109 110 111 112 ... 141 142

Kommentare zu diesen Handbüchern

Keine Kommentare