– 4.24 –
[Wiring check]
After the heater has been attached, be sure to check.
1) Set both selectors to 110V.
Make sure that the resistance between A1 to A4 is the following value.
JV3-130S 37- 43
JV3-160S 30- 36
Make sure that the resistance between A5 to A8 is the following value.
JV3-130S/160S 46- 55
2) Set both selectors to 220V.
Make sure that the resistance between A1 to A4 is the following value.
JV3-130S 145- 175
JV3-160S 120- 145
Make sure that the resistance between A5 to A8 is the following value.
JV3-130S/160S 185- 220
3) After confirmation, restore the voltage of the both selectors to the voltage used previously.