2-4
Setting the media
1
Open the table front cover.
2
Set media along the L-shaped mark (drawing
origin) on the right corner of the table.
To change the drawing origin, see the following page.
( P.3-2 "Changing origin")
• To use tools, set into the shaves (8.0 mm-deep) on the corners
of the table.
3
Close the table front cover, and press the key.
The origin is detected. Please wait until the operation is finished.
4
Adjust the table to an appropriate height for drawing by pressing the
TABLE keys, and press the key.
When the media thickness is 100mm and less, media inflation is required so that the media thickness
may be 100mm.
When the media thickness is 100mm and more, it is necessary to align it with the drawing height with
the table up/ down key.
The peripheral parts of the media could roll up due to heat. Fix the media supplementarily using
adhesive tapes, etc.
Adjust the height of the table with the media to 150 mm or less.
ENTER
ENTER