Setting the Head Height
For the head height setting, you can set the items below:
Height of vacuum table and table spacer
Media thickness
Head gap
Table height
Gap check
Setting the table spacer
When you use the vacuum table and the table spacer depending on the media thickness, set the height of
“vacuum table + table spacer”. (Supported from the firmware ver.3.00)
1
Press the key in the local mode.
2
Select the [HEAD HEIGHT] by pressing the or
key, and press the key.
3
Select the [TABLE SPACER] by pressing the or
keys, and press the key.
4
Press the or keys and set the table spacer
height, and then press the key.
•Set Value100mm, 50mm, 0mm
5
Press the key several times to end the setting.
When you set the media thickness of 100mm, it is necessary to attach the vacuum table and the table
spacer so that the media thickness may become 100mm.
<LOCAL>
FUNCTION
FUNCT I ON
WOR K S E T < E N T >
ENTER
HEAD HE I GHT
TABLE SPACER <en t >
ENTER
HEAD HE I GHT
TABLE SPACER: 100mm
ENTER
END