1-17
1
Before Use
<LOCAL>and<REMOTE>
<LOCAL> and <REMOTE> are shown on the display of this machine.
LOCAL
When <LOCAL> is diplayed, the followings can be set.
All keys are available.
It receives the data from the computer. However, drawing is not executed.
Set the drawing origin or drawing area with the Jog keys.
Execute “Test drawing” with the key.
Execute “Head cleaning” with the key.
Execute function settings with the key.
Press the key to set each function of the UV lamp.
Check the remaining amout of ink, the model name, the firmware version, and so on with the the
key.
Switch between [REMOTE] and [LOCAL] with the key.
Erase the drawing data that this machine has received with the key.
Press the key to switch ON/OFF of the vacuum.
By pressing the key and then the jog key, you can move the table up and down.
REMOTE
When <REMOTE> is displayed, the received data is drawn.
Press the key to suspend this machine and to return to [LOCAL].
Press the to start <REMOTE>.
<LOCAL . 1>
*REMOTE. 1*
CLEANING
FUNCTION
UV
ENTER
REMOTE
DATA CLEAR
VACUUM
TABLE
REMOTE
REMOTE