Turning the power ON/OFF
2-10
When turning the power OFF
Do not turn the main power switch OFF.
If the main power switch is ON, the power periodically turns on and the nozzle dropout prevention function
is operated.
If the main power switch is OFF, the sleep function does not work and this may cause nozzle dropout.
Turn the power OFF after confirming the head position.
If the emergency stop switch is pressed or the main power supply switch is turned OFF, the head may stop
at the position other than the waiting position.
Turning the power off when the head does not return to the position in readiness (the left side) may dry the
head and may cause nozzle clogging.
In this case, turn the power ON again, confirm that the head has returned to the position in readiness (the
left side), then turn the power OFF.
Do not turn the power OFF in drawing.
The head may not return to the position in readiness (the left side).
Before turning the main power OFF, turn the front power switch OFF.
When turning the main power switch off to move this machine or to solve an error, be sure to press the
power switch on the front, confirm that the power is off, then turn the main power switch OFF.