Changing origin
3-3
3
Useful Function
Changing origin with FUNCTION menu
To precisely set the origin of coordinates, set its X- and Y- coordinates from the FUNCTION menu. This
setting value becomes the origin position (0, 0).
1
Press the key in the local
mode.
2
Select the [ORIGIN] by pressing the
or key, and press the
key twice.
X-axis offset value setting screen is displayed.
3
Input value by pressing the
or keys, and press the
key.
Setting the origin position of X-axis.
The value in the parentheses indicates the distance from the origin to the maximum
effective area.
4
Select the [Y OFFS] by pressing the
or keys, and press the
key.
5
Input value by pressing the or
keys, and press the key.
Setting the origin position of Y-axis.
The value on the first line indicates the distance from the origin to the maximum effective
range.
6
Press the key several times to end the setting.
The set value remains even if turning off the power.